{"id":3494,"date":"2019-11-02T12:25:00","date_gmt":"2019-11-02T12:25:00","guid":{"rendered":"https:\/\/maan-engineering.com\/?post_type=componenten&#038;p=3494"},"modified":"2020-05-22T08:18:53","modified_gmt":"2020-05-22T08:18:53","slug":"ir-station-2","status":"publish","type":"componenten","link":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/","title":{"rendered":"IR Station"},"content":{"rendered":"\n<a href=\"https:\/\/maan-engineering.com\/en\/hotmelt-flat-lamination-2\/products\/components\/\" target=\"_self\" role=\"button\" rel=\"noopener noreferrer\">\n\t\t\t\t\t\t\tBack to overview\n\t\t\t\t\t<\/a>\n<h1>\n\t<\/h1>\n\t<p>When a coating is being applied to relatively cold materials, it is advisable to pre-treat these materials using infrared heating. The recommended temperature for the effective adhesion of hotmelt on a panel is between 20\u00b0C and 35\u00b0C. One major benefit of IR heating is that it does not require long start-up times. Compared to conventional drying and heating technologies, this results in considerable time savings.<\/p>\n\t<h2>USPs<\/h2>\n<p>+ Fast warm-up time<\/p>\n<p>+ Can be fitted with a \u0394T control for process control<\/p>\n    Interested in further information on the ?<br>\n    Then download the technical data sheet.\n\t\t\t<a href=\"\" target=\"_self\" role=\"button\" rel=\"noopener noreferrer\">\n\t\t\t\t\t\t\tDownload data sheet\n\t\t\t\t\t<\/a>\n<h4>\n\t\tCalibrating to the application\n\t<\/h4>\n<p>For every process, we determine the IR radiator and wavelength most suitable for your application in order to offer you the most energy-efficient solution possible. Under \u201cIR applications\u201d you can find references to projects carried out.<\/p>\n<h4>\n\t\tPrecision\n\t<\/h4>\n<p>The precision control of the processes results in faster drying and better gluing or melting \u2013 and consequently a higher product quality and reduced production risks and product waste. Infrared heating can greatly benefit the gluing of difficult materials under tensile or compressive stresses, of curved surfaces and mass production. Faster drying offers a better adhesion of edges and corners that can come unstuck in the event of insufficient drying of the glue.<\/p>\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/11\/IR-Station-Controls_jpeg_resized.jpg\" alt=\"IR-Station-Controls_jpeg_resized\" itemprop=\"image\" height=\"2000\" width=\"2000\" title=\"IR-Station-Controls_jpeg_resized\" onerror=\"this.style.display='none'\">\n\t\t\t\t<img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/11\/Phone-call.jpg\" alt=\"Phone-call\" itemprop=\"image\" height=\"1333\" width=\"2000\" title=\"Phone-call\" onerror=\"this.style.display='none'\">\n<h5>\n\t\tFIND OUT MORE?\n\t<\/h5>\n\t<p>Learn more about the ? Please contact our Hotmelt Flat Lamination sales team.<\/p>\n\t\t\t<a href=\"tel:++31621856257\" role=\"button\" target=\"_self\" rel=\"noopener noreferrer\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tCall : +31 (0)6 218 562 57\n\t\t\t\t\t\t\t<\/a>\n\t\t\t<a href=\"mailto:W.Florijn@maan-engineering.com\" role=\"button\" target=\"_self\" rel=\"noopener noreferrer\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\tEmail: W.Florijn@maan-engineering.com\n\t\t\t\t\t\t\t<\/a>\n","protected":false},"excerpt":{"rendered":"<p>Back to overview When a coating is being applied to relatively cold materials, it is advisable to pre-treat these materials using infrared heating. The recommended temperature for the effective adhesion of hotmelt on a panel is between 20\u00b0C and 35\u00b0C. One major benefit of IR heating is that it does not require long start-up times.&hellip;<\/p>\n","protected":false},"featured_media":2005,"parent":0,"template":"","meta":{"_acf_changed":false,"footnotes":""},"categories":[154],"tags":[],"applications":[],"merk":[],"type_behandeling":[148],"type_component":[],"options":[],"class_list":["post-3494","componenten","type-componenten","status-publish","has-post-thumbnail","hentry","category-sheet-2-sheet-en","type_behandeling-pre-treatment"],"acf":{"datasheet":"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/10\/TDS_MENG_S2S_IR_2019_EN.pdf"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>IR Station - Maan Engineering<\/title>\n<meta name=\"robots\" content=\"noindex, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"IR Station - Maan Engineering\" \/>\n<meta property=\"og:description\" content=\"Back to overview When a coating is being applied to relatively cold materials, it is advisable to pre-treat these materials using infrared heating. The recommended temperature for the effective adhesion of hotmelt on a panel is between 20\u00b0C and 35\u00b0C. One major benefit of IR heating is that it does not require long start-up times.&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Maan Engineering\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-22T08:18:53+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/11\/IR-Station-Controls_jpeg_resized.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"2000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/\",\"url\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/\",\"name\":\"IR Station - Maan Engineering\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/maan-engineering.com\\\/wp-content\\\/uploads\\\/2019\\\/11\\\/IR-Station-Controls_jpeg_resized.jpg\",\"datePublished\":\"2019-11-02T12:25:00+00:00\",\"dateModified\":\"2020-05-22T08:18:53+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/maan-engineering.com\\\/wp-content\\\/uploads\\\/2019\\\/11\\\/IR-Station-Controls_jpeg_resized.jpg\",\"contentUrl\":\"https:\\\/\\\/maan-engineering.com\\\/wp-content\\\/uploads\\\/2019\\\/11\\\/IR-Station-Controls_jpeg_resized.jpg\",\"width\":2000,\"height\":2000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/componenten\\\/ir-station-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"IR Station\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/\",\"name\":\"Maan Engineering\",\"description\":\"Coating Equipment for the building &amp; construction industry and label industry\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/maan-engineering.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"IR Station - Maan Engineering","robots":{"index":"noindex","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"og_locale":"en_US","og_type":"article","og_title":"IR Station - Maan Engineering","og_description":"Back to overview When a coating is being applied to relatively cold materials, it is advisable to pre-treat these materials using infrared heating. The recommended temperature for the effective adhesion of hotmelt on a panel is between 20\u00b0C and 35\u00b0C. One major benefit of IR heating is that it does not require long start-up times.&hellip;","og_url":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/","og_site_name":"Maan Engineering","article_modified_time":"2020-05-22T08:18:53+00:00","og_image":[{"width":2000,"height":2000,"url":"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/11\/IR-Station-Controls_jpeg_resized.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/","url":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/","name":"IR Station - Maan Engineering","isPartOf":{"@id":"https:\/\/maan-engineering.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/#primaryimage"},"image":{"@id":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/#primaryimage"},"thumbnailUrl":"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/11\/IR-Station-Controls_jpeg_resized.jpg","datePublished":"2019-11-02T12:25:00+00:00","dateModified":"2020-05-22T08:18:53+00:00","breadcrumb":{"@id":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/#primaryimage","url":"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/11\/IR-Station-Controls_jpeg_resized.jpg","contentUrl":"https:\/\/maan-engineering.com\/wp-content\/uploads\/2019\/11\/IR-Station-Controls_jpeg_resized.jpg","width":2000,"height":2000},{"@type":"BreadcrumbList","@id":"https:\/\/maan-engineering.com\/en\/componenten\/ir-station-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/maan-engineering.com\/en\/"},{"@type":"ListItem","position":2,"name":"IR Station"}]},{"@type":"WebSite","@id":"https:\/\/maan-engineering.com\/en\/#website","url":"https:\/\/maan-engineering.com\/en\/","name":"Maan Engineering","description":"Coating Equipment for the building &amp; construction industry and label industry","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/maan-engineering.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/componenten\/3494","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/componenten"}],"about":[{"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/types\/componenten"}],"version-history":[{"count":5,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/componenten\/3494\/revisions"}],"predecessor-version":[{"id":4718,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/componenten\/3494\/revisions\/4718"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/media\/2005"}],"wp:attachment":[{"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/media?parent=3494"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/categories?post=3494"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/tags?post=3494"},{"taxonomy":"applications","embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/applications?post=3494"},{"taxonomy":"merk","embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/merk?post=3494"},{"taxonomy":"type_behandeling","embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/type_behandeling?post=3494"},{"taxonomy":"type_component","embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/type_component?post=3494"},{"taxonomy":"options","embeddable":true,"href":"https:\/\/maan-engineering.com\/en\/wp-json\/wp\/v2\/options?post=3494"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}